Products ► Instrumentation ► Analogue Output Signal Conditioners ► Model ALA5
Model ALA5
ATEX Approved
Product features:
- ATEX certificated amplifier for hazardous zones 0, 1 & 2
- Designed for fitting in-line to strain gauge sensors such as load cells
- Intrinsically safe to EN60079-11
- Provides 2-wire 4-20 mA current loop output
- Environmentally sealed to IP67
- Fast calibration via gain and offset trim
- Bridge impedance min 350 Ohms max 5,000 Ohms
- Wide temperature range -40 C to +85 C
- Supplied with 1 m strain gauge cable and 5m output cable
- Robust design, reverse polarity & short circuit protected
Description
The ALA5 incorporates an ATEX certified 4-20 mA load cell amplifier designed for operation within hazardous zones 0,1 & 2
The high performance ATEX 4-20 mA load cell amplifier provides 2-wire 4-20 mA current loop output and connects in-line for a range of signal conditioning for strain gauges, load cells, pressure and torque transducers. Intrinsically safe to EN60079-11 (previously EN 50020) standards.
The ALA5 can be connected to ATEX approved equipment within the hazardous zone or to non-approved ATEX equipment outside the hazardous zone provided that a suitable barrier is used.
Designed for fitting in-line to strain gauge sensors such as load cells, the amplifier is housed within a stainless steel IP67 NEMA 6 EMC protected enclosure and is supplied with 1m strain gauge cable and 5 m output cable.
An OEM option is available for customers wishing to embed the ATEX amplifier within a sensor. Please note: the ICA5ATEX is approved for incorporation into load cells and other enclosures. Please contact us to discuss your requirements.