Categories
Digital Output Signal Converters

Model EVAL KIT

Embedded & PCB Modules

Evaluation Kits for DCell & DSC

  • An ideal, low cost way for first time users to familiarise with the digitiser modules in test situations and discover the benefits of the DCell/DSC
  • RS232, RS485 and CAN Kits available
  • One ‘FREE’ DCell or DSC is included in the cost of the kit – mounted and ready to go (the DCell is soldered to the mount and the DSC is screwed to mount)
  • The kit includes everything you need to communicate with the DCell or DSC card from your PC
Categories
Digital Output Signal Converters

Model DSJ1

Accessories

Mount Board for a Single Digital Load Cell Converter

  • Bus connections for communication and power supply
  • 2 part connectors for field terminals
  • D type 9 pin connecter for easy RS232 connection
  • Green LED power indicator
  • Red LED digital output indicator
  • Push switch to simulate digital input
  • CAN compliant – option
  • Choose & add the DSC digital strain card required to fit onto the DSJ1
Categories
Digital Output Signal Converters

Model DSJ4

Accessories

Mount Board for 4 x Digital Load Cell Converters

  • PCB only – for housing 4 x DSC digital load cell converter cards
  • Bus connections for communication and power supply
  • 2 part connectors for field terminals
  • LED power indicator
  • CAN compliant – option
  • Option of a waterproof IP65 enclosure NEMA4 bulkhead mounting in grey ABS or stainless steel case
Categories
Controllers & Alarms

Model LCA20

Bulkhead

Load Cell Amplifier with Relays Data Port & Display for Weighing

  • Full digital set–up using PC or keypad
  • 3 x configurable digital inputs e.g. for autotare, peak hold and reset
  • RS485 and RS232 digital data output for communications and printing
  • Measurement speeds of 10 / 80 samples per sec
  • Factory calibration in mV/V
  • 5 V excitation supports up to 10 x 350 R load cells
  • Fully isolated 4-20 mA and 0-10 V analogue outputs
Categories
Controllers & Alarms

Model LCI

Bulkhead

Load Cell Junction Box & Fault Monitoring Alarm

  • For the protection of multi-load cell installations such as silos and tanks
  • Reduces down-time via immediate alarm and fault diagnosis
  • Provides an assured working system in critical applications
  • Avoids material shortage, overflow or incorrect batching from damaged load cells or cables
Categories
Controllers & Alarms

Model LCB20

DIN Rail & PCB Modules

OEM Load Cell Amplifier and Digitiser PCB

  • PCB version of the load cell amplifier display for weighing (LCA20)
  • Simple auto calibration
  • 5 V excitation supporting up to 10 x load cells (350 R)
  • 0.5 to to 7.8 mV/V sensitivity
  • 6 wire input to compensate for barrier and cable losses
Categories
Bluetooth Telemetry

Model B24-SSB

Bluetooth Strain Transmitter

  • Wide sensitivity input – choose from +/- 6mV/V, +/- 12 mV/V, +/- 24 mV/V, +/- 48mV/V
  • Noise free resolution up to 110,000 counts (16.75 bit)
  • Up to 3 months of continuous use at three samples per second.
  • Monitor up to 12 transmitters by a single device, or multiple devices
Categories
Analogue Output Signal Conditioners

Model LVDT OBSOLETE

Bulkhead

LVDT Signal Conditioner and Amplifier

  • LVDT sensor excitation of 4.5 V RMS is provided
  • Selectable sensitivity from 20 mV to 10 V and fine trim with potentiometer
  • Analogue outputs of 4-20 mA & 0-10 V
  • Selectable excitation frequency between 1 and 5 kHz
Categories
Analogue Output Signal Conditioners

Model SGA A&D

Bulkhead

Strain Gauge Signal Conditioning for Load Cells

  • Strain gauge amplifier ideal for load cell signal conditioning
  • Bridge excitation of 10 V DC with drive for four 350 Ohm load cells
  • Conditioned output signal can be selected from 0-20 mA, 4-20 mA, 0-10 V, 0-5 V, ±5 V or ±10 V
  • 1 – 5 kHz adjusted filter for test & measurement applications
Categories
Analogue Output Signal Conditioners

Model SGABCM

Bulkhead

Bridge Completion Module for the SGA

  • Easy installation – simply screws into the existing load cell connector on the SGA
  • On-board screw terminal connections accept a wide range of bridge completion resistor enabling on-site installation without soldering equipment
  • High stability resistors (5ppm/°C) fitted for the ‘fixed’ arms of the bridge
Categories
Analogue Output Signal Conditioners

Model ILA

In-Line

In-line Strain Gauge or Load Cell Analogue Amplifier

  • Quick setup & semi-automatic calibration via USB programmer module and free Toolkit software
  • High accuracy measurement
  • Low temperature drift provides stable, reliable measurement
  • Extensive EMC filtering reduces noise for safe operation
  • Small robust design, ideal for compact installations – 80 x 24 x 15 mm
Categories
Analogue Output Signal Conditioners

Model ILE

In-Line

In-Line Housing for Load Cell Amplifiers and Digital Converters

  • In-line housing for load cell amplifiers ICA and digital load cell converters DCell
  • The ILE and ICA converts a load cell to a conditioned load cell
  • The ILE and DCell converts load cell to a digital load cell
  • Very small size – 56 x 28 mm excluding glands
  • Machined from solid stainless steel
  • Waterproof to IP67 NEMA
Categories
Analogue Output Signal Conditioners

Model ALA5

ATEX Approved

ATEX Certified 4-20 mA Load Cell Amplifier

  • ATEX certificated amplifier for hazardous zones 0, 1 & 2
  • Designed for fitting in-line to strain gauge sensors such as load cells
  • Intrinsically safe to EN60079-11
  • Provides 2-wire 4-20 mA current loop output
  • Environmentally sealed to IP67
Categories
Analogue Output Signal Conditioners Controllers & Alarms

Model LCD20

DIN Rail

Load Cell Signal Amplifier

  • Intelligent, compact, stackable microprocessor based load cell amplifier for smarter automation and process control
  • Fully isolated standard analogue outputs 4-20mA and 0-10V
  • Full digital setup & easy programming via USB connection to a PC using intuitive toolkit software
Categories
Analogue Output Signal Conditioners

Model JBA

DIN Rail

Active Summing Load Cell Junction Box

  • Accurate and easy summation of up to 4 strain gauge load cells
  • Corner correction enabled to compensate for manufacturing tolerances and loading in multiple strain gauge installations
  • Individual gain adjustment provided for each channel
  • Simplifies installation of multi-cell platforms, silos, tanks and hopper weighing systems
Categories
Analogue Output Signal Conditioners

Model ICA5ATEX

Embedded

ATEX Certificated Miniature Load Cell Amplifier

  • ATEX certificated amplifier for hazardous zones 0, 1 & 2
  • Miniature PCB format for fitting inside sensors, 19 mm diameter, 7.6 mm height
  • 2 wire current loop 4-20 mA output
  • Low interaction between the trimmers makes calibration fast and easy
Categories
Analogue Output Signal Conditioners

Model ICA H & S

Embedded

Miniature Strain Gauge Amplifier

  • Fits inside sensors, 19.5 mm diameter, 7.6 mm height
  • Outputs of 4-20 mA, 0-10 V, 0-5 V, ±10 V
  • Non interaction between the trimmers makes calibration fast and easy
  • High speed 1000 Hz
  • 2 wire 4-20 mA load cell option
Categories
News

The New B24 Bluetooth® System
Wireless Strain Monitoring


The new Bluetooth® system sends data straight to your smart device, making multi-channel wireless strain monitoring affordable for smaller scale applications.