Categories
Ultrasonic Sensors

Model UFP / UPA

Cylindric / Cuboid , < 6000 mm

  • Measurement range: 25…6000 mm
  • Resolution max.: 0.125 mm
  • Linearity max.: ±0.3 %
  • Protection class: < IP67
  • Output: 0…10 V, 4…20 mA, switching output
Categories
Ultrasonic Sensors

Model UPT

Cuboid, < 3500 mm

  • Measurement range: 30…3500 mm
  • Resolution max.: 0.125 mm
  • Linearity max.: ±0.5 %
  • Protection class: < IP67
  • Output: 0…10 V, 4…20 mA, switching output
Categories
Ultrasonic Sensors

Model UFA2-200

Cylindrical, < 200 mm

  • Measurement range: 0…150 mm, 20…200 mm
  • Resolution max.: 1 mm
  • Linearity max.: ±0.4 %
  • Protection class: IP67
  • Output: 0…10 V, 4…20 mA, switching output
Categories
Ultrasonic Sensors

Model UFA2-1500

Cylindrical, < 1500 mm

  • Measurement range: 150…1500 mm
  • Resolution max.: 1 mm
  • Linearity max.: ±0.4 %
  • Protection class: IP67
  • Output: 0…10 V, 4…20 mA, switching output
Categories
Ultrasonic Sensors

Model UFA2-6000

Cylindrical, < 6000 mm

  • Measurement range: 600…6000 mm
  • Resolution max.: 1 mm
  • Linearity max.: ±0.4 %
  • Protection class: IP67
  • Output: 0…10 V, 4…20 mA, switching output
Categories
Ultrasonic Sensors

Model UPK

Cylindrical, < 1200 mm

  • Ranges: 40…300 mm, 60…800 mm, 80…1200 mm
  • Resolution max.: 2 mm
  • Linearity max.: ±1 %
  • Protection class: IP67
  • Output: 0…10 V, 4…20 mA, NPN, PNP
Categories
Ultrasonic Sensors

Model UBA

Ultrasonic Fork, < 40/70 mm

  • Application: Ultrasonic fork for edge control
  • Repeatability: 0.1 mm
  • Linearity: ±1 %
  • Protection class: IP67
  • Output: 0…10 V
Categories
Ultrasonic Flow Meters

Model SONOELIS SE404x / SE406x

Mains- powered, < 12 inch

  • Dimension range: DN32 to DN300
  • Two basic designs: single-beam (SE 404x) and dual-beam (SE 406x)
  • Three variants of electronics: COMFORT (electrical outputs, display, keyboard), STANDARD (electrical outputs, display) and ECONOMIC (without display, electrical outputs only)
  • Temperature of the measured liquid 0°C to 150°C
  • Outputs: pulse, frequency 
Categories
Ultrasonic Flow Meters

Model SONOELIS SE404x.1 / SE406x.1

Mains- powered, < 12 inch

  • Dimension range: DN32 to DN300
  • Two basic designs: single-beam (SE 404x.1) and dual-beam (SE 406x.1)
  • Two variants of electronics: ECONOMIC (electrical output only) and COMFORT (keyboard, display and electrical outputs)
  • Temperature of the measured liquid 0°C to 150°C
  • Outputs: pulse, frequency 
Categories
Ultrasonic Flow Meters

Model SONOELIS SE401x / SE402x

Mains- powered, < 48 inch

  • Dimension range: DN200 to DN1200
  • Two basic designs – single-beam (SE 401x) and dual-beam (SE 402x)
  • Three different variants of electronics: ECONOMIC (electrical outputs), STANDARD (display, electrical outputs), COMFORT (display, keyboard, electrical outputs)
  • Temperature of the measured liquid 0°C to 150°C
  • Electrical outputs: pulse, frequency
Categories
Ultrasonic Flow Meters

Model SONOELIS SE401x.1 / SE402x.1

Mains- powered, < 48 inch

  • Dimension range: DN200 to DN1200
  • Two basic designs – single-beam (SE 401x.1) and dual-beam (SE 402x.1)
  • Two variants of electronics: ECONOMIC (electrical outputs) and COMFORT (display, keyboards, electrical outputs)
  • Temperature of the measured liquid 0°C to 150°C
  • Electrical outputs: pulse, frequency
Categories
Ultrasonic Flow Meters

Model SONOELIS SE4041

Mains- powered, < 12 inch

  • Dimension range: DN32 to DN300
  • Remote ECONOMIC design (without display and keyboard)
  • Temperature of the measured liquid 0°C to 150°C
  • Pulse output
  • MID TCM 142/16 – 5353 certification for billing measurement of heat and cold energy
Categories
Ultrasonic Flow Meters

Model SONOELIS SE4011

Mains- powered, < 48 inch

  • Wide range of dimensions: DN200 to DN1200
  • Temperature of the measured liquid 0°C to 150°C
  • Nominal pressure class: PN10
  • Pulse output
  • Certification MID TCM 142/16 – 5353 for billing measurement of heat and cold energy
Categories
Ultrasonic Flow Meters

Model SONOELIS SE4015.xT

Mains- powered, < 8 inch

  • For dimensions DN80 to DN200
  • Three variants – ECONOMIC (electrical outputs), STANDART (electrical outputs and display) and COMFORT (electrical outputs, display and keyboard)
  • The measured water can reach a temperature up to 150°C and pressure up to 240 bar
  • Electrical outputs: pulse and frequency
Categories
Ultrasonic Flow Meters

Model SONOELIS SE401x.x- / SE402x.xRP

Mains- powered, < 48 inch

  • Dimension range: DN400 to DN1200
  • 3 variants of the evaluating electronics: COMFORT (display, keyboard, electrical outputs), STANDARD (display, electrical outputs) or ECONOMIC (electrical outputs)
  • Maximum temperature during removing/changing of transductors from a sensor is 40°C
  • Electrical outputs: pulse, frequency
Categories
Ultrasonic Flow Meters

Model SONOELIS SE804x.x / SE806x.x

Mains- powered, < 48 inch

  • Dimension range: DN200 to DN1200
  • Two variants of the evaluating electronics: COMFORT (display, keyboard, electrical outputs) or ECONOMIC (electrical outputs)
  • Temperature of the measured liquid 0°C to 150°C
  • Outputs: pulse, frequency 
Categories
Ultrasonic Flow Meters

Model FLOMIC FL503x / FL505x

Battery- powered, < 12 inch

  • Dimension range: DN32 to DN300
  • Two basic designs – single-beam (FL503x) and double-beam (FL505x)
  • Compact or remote version
  • Temperature: 50°C to 130°C
  • Pressure: PN16 (150psi) or PN40 (600 psi)
  • Period of measurement: 1 s
  • Power supply of Li battery 3.6 V/19Ah with a lifetime of 8 years
Categories
Ultrasonic Flow Meters

Model FLOMIC FL3085

Battery- powered, < 48 inch

  • Dimension range: DN200 to DN1200
  • Single-beam design
  • Installation in remote locations without electricity
  • Power supply of Li batteries 3.6 V / 19Ah + 2pcs of alkaline batteries 9V, life 4 years
  • Protection of transductors: IP54
  • Protection of the evaluating electronics: IP65
  • Temperature of the measured liquid from 0°C to 150°C
  • Nominal pressure PN10 (150 psi)
Categories
Ultrasonic Flow Meters

Model FLOMIC FL3005

Battery- powered, < 80 inch

  • Dimension range: DN200 to DN2000
  • Single-beam design
  • Power supply of Li batteries 3.6 V / 19Ah + 2pcs of alkaline batteries 9V, life 4 years
  • Temperature of the measured liquid from 0°C to 150°C
  • Protection of transductors: IP54
  • Protection of the evaluating electronics: IP65
  • Nominal pressure PN40 (600 psi)
Categories
Ultrasonic Flow Meters

Model FLOMIC FL5034F

Battery- powered, < 4 inch

  • For dimensions DN65, DN80 and DN100
  • It checks and measures the total flow volume and instantaneous flow
  • All-stainless steel design with a special threaded connection for fire hoses and a holder for carrying in the field
  • Temperature: 50°C
  • Pressure: PN16 (150 psi)
  • Protection: IP68